Detail SST 2000
SST-2000ATM and SST-2000HTM
Series Speed Switches/ Transmitters
receive signal input from
a passive or active magnetic
pickup, shaft encoder, contact
closure, flowmeter, etc., toprovide
proportional analog outputs and
either 0, 2, or 4 relay trip setpoints
Proportional outputs of either 4– 20 mA ( standard) ,
0– 5 Vdc, or 0– 10 Vdc are field-selectable.
Standard 0-1 mAdc meter output included.
Models available with up to four alarm setpoints.
Field-selectable frequency range.
Field-adjustable sensitivity control.
Field-programmable for many types of sensors,
including contact closure input.
Repeater output drives counters and self-powered
digital tachometers such as Dynalco’ s SPD-100
and SPD-700.
Regulated 14 Vdc output powers active pickups
( e.g. M910) , accessories, and digital meters
such as DPM-105 or MTH-103D, and the 12 Vdc
versions of the internally lighted SPD-100L and
LST-100L.
Alarms are field-configurable for DPDT
( SST-2400 A or -H only) , overspeed, underspeed,
energize, de-energize, latch, auto-reset.
Integral VERIFY, requires external meter. Permits
viewing and setting of setpoint value without
actuating the relays.
Input Frequency: Full-scale values from
0– 0.1Hz ( 6 pulses per minute) to 0– 50, 000 Hz.
Function: Converts frequency input ( speed, rate)
into linear proportional dc output. Provides alarm
setpoints for over- and underspeed control and
for sequential, startup, and shutdown switching.
Applications: Includes engines, machines, I/ P
drivers, instrumentation, process control,
recording, measurement.
Signal Sources: Includes magnetic pickups, ac
generators, contact closures, photocells.
Output Range Capability: Current source up to
50 mAdc output always included.
Alarm Setpoints: Available with two or four
relays. Also available with no relays if only
proportional outputs are required.